Husdata 
Värmepump
43.00 kWh

Total
0.46 kWh
Aktuell driftsinfo IVT C7.
E L M Ä T A R E I D AG

Värmepump
Uträknad
44.81 kWh
Dagens statistik uppdateras varje minut. Senast klockan 21:06:00
| | Temperaturer | | | | |
| | Namn | Aktuellt | Medel | Max | Min |
| | Radiator Retur GT1 | 33.8° | 32.5° | 34.1° | 28.1° |
| | Ute GT2 | -14.8° | -10.1° | -6.3° | -14.8° |
| | Varmvatten GT3 | 42.4° | 44.3° | 51.1° | 41.0° |
| | Framledning Rad GT4 | 0.0° | 0.0° | 0.0° | 0.0° |
| | Rum GT5 | 21.6° | 21.3° | 21.6° | 20.9° |
| | Hetgas GT6 | 85.0° | 81.6° | 93.2° | 29.0° |
| | Värmebärare Ut GT8 | 42.5° | 42.6° | 56.7° | 31.5° |
| | Värmebärare In GT9 | 37.2° | 36.2° | 41.6° | 31.4° |
| | Köldbärare In GT10 | 3.2° | 3.4° | 3.6° | 3.2° |
| | Köldbärare Ut GT11 | -2.2° | -1.4° | 1.1° | -2.2° |
| | Varmvatten GT3x | 0.0° | 0.0° | 0.0° | 0.0° |
| |
| | Driftstider | | | | |
| | Namn | Akt.status | kWh | Drifttid | Starter |
| | Köldbärarpump P3 | ON | 2.20 | 20:42:23 | 1 |
| | Kompressor | ON | 38.31 | 20:42:35 | 1 |
| | Tillskott steg 1 | OFF | 0.89 | 00:17:42 | 3 |
| | Tillskott steg 2 | OFF | 1.30 | 00:13:00 | 1 |
| | Radiatorpump P1 | ON | 1.16 | 21:05:09 | 0 |
| | Värmebärarpump P2 | ON | 0.95 | 20:41:39 | 1 |
| | Växelventil VXV1 | OFF | 0.00 | 01:33:16 | 9 |
| | Summa larm | OFF | 0.00 | 00:00:00 | 0 |
| |